Spec Value
Output Type Transistor
CPU 32-bit CPU and ASIC dual processors that support floating point operations.
Program Memory 64 Mbytes
Power Supply Voltage 24 VDC (-15% ~ 20%) (DC input power polarity reversal protection)

Description

Technical Specifications of Delta 4K PLC Program HMI TP70P-211LC1T:

Delta 4K PLC Program HMI TP70P-211LC1T Technical Specifications:

32-bit CPU and ASIC dual processors that support floating point operations.

24 VDC (-15% ~ 20%) (DC input power polarity reversal protection)

DC input power polarity reversal protection

ESD (IEC 61131-2, IEC 61000-4-2): 8 kV air discharge EFT (IEC 61131-2, IEC 61000-4-4): Power line: 2 kV, Digital I/O: 1 kV, Analog & Communication I/O: 1 kV Damped-Oscillatory Wave: Power Line: 1 kV, Digital I/O: 1 kV RS (IEC 61131-2, IEC 61000-4-3): 26 MHz~1 GHz, 10 V/m

ESD (IEC 61131-2, IEC 61000-4-2): 8 kV air discharge EFT (IEC 61131-2, IEC 61000-4-4): Power line: 2 kV, Digital I/O: 1 kV, Analog & Communication I/O: 1 kV Damped-Oscillatory Wave: Power Line: 1 kV, Digital I/O: 1 kV RS (IEC 61131-2, IEC 61000-4-3): 26 MHz~1 GHz, 10 V/m

Transfer of thermal energy via convection

Brand

Delta

Specification

Specification Value
Output Type Transistor
DI 17
DO 24
AI*2
AO*2 4(I)
CPU 32-bit CPU and ASIC dual processors that support floating point operations.
Program Memory 64 Mbytes
Power Supply Voltage 24 VDC (-15% ~ 20%) (DC input power polarity reversal protection)
Power Consumption 24W
Power Protection DC input power polarity reversal protection
Insulation resistance > 5 MΩ (The voltage between all I/O terminals and the ground is 500 V DC.)
Noise Immunity ESD (IEC 61131-2, IEC 61000-4-2): 8 kV air discharge EFT (IEC 61131-2, IEC 61000-4-4): Power line: 2 kV, Digital I/O: 1 kV, Analog & Communication I/O: 1 kV Damped-Oscillatory Wave: Power Line: 1 kV, Digital I/O: 1 kV RS (IEC 61131-2, IEC 61000-4-3): 26 MHz~1 GHz, 10 V/m
Ground The diameter of the ground used should not be less than the diameters of the wires connected to the power terminals of the PLC used. (If several PLCs are used simultaneously, please use single-point ground.)
Operating Temperature 0°C~50°C Relative humidity: 20%~90% RH【0~40°C】,10%~55% RH【41~50°C】 Pollution degree 2 (No condensation)
Storage Temperature -20°C~60°C
Waterproof Class of the Front Panel Transfer of thermal energy via convection
Vibration/Shock resistance International standards IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
Cooling method Transfer of thermal energy via convection
Dimensions 205.6 x 142.6 x 87.7
Weight 900 g